HomeProductsDSO1000E Series
DSO1000E Series
HANTEKOscilloscopes
Model: DSO1000E

DSO1000E Series

Price:Price on Request

Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.

Key Specifications

Sample ModesDSO1072E: Real-Time Sample
Acquisition ModesDSO1072E:  
NormalDSO1072E: Normal data only
Peak DetectDSO1072E: High-frequency and randon glith capture
Contact Us
View on Manufacturer's Website
Sample ModesDSO1072E: Real-Time Sample
Acquisition ModesDSO1072E:  
NormalDSO1072E: Normal data only
Peak DetectDSO1072E: High-frequency and randon glith capture
AverageDSO1072E: Wavefom Average, selectable 4,8,16,32,64,128
Inputs CouplingDSO1072E: AC, DC, GND
Inputs ImpendanceDSO1072E: 1MΩ±2% ‖ 20pF±3pF
Probe AttenuationDSO1072E: 1X, 10X
Supported Probe Attenuation FactorDSO1072E: 1X, 10X, 100X, 1000X
Maximum Input VoltageDSO1072E: CAT I and CAT II: 300VRMS (10×), Installation Category; CAT III: 150VRMS (1×)
Sample Rate RangeDSO1072E: 1GS/s
Waveform InterpolationDSO1072E: (sin x)/x
Record LengthDSO1072E: 2M
SEC/DIV RangeDSO1072E: 4ns/div~2000s/div, in a 2, 4, 8 sequence | DSO1102E: 2ns/div~2000s/div, in a 2, 4, 8 sequence
Sample Rate and Delay Time AccuracyDSO1072E: ±50ppm over any ≥ 1ms time interval
Scanning Speed RangeDSO1072E: 4ns/div to 8ns/div; (-8div x s/div) to 40ms; 20ns/div to 80μs/div;(-8div×s/div) to 40ms 200μs/div to 40s/div; (-8div×s/div) to 400s | DSO1102E: 2ns/div to10ns/div; (-4div×s/div) to 20ms;
Delta Time Measurement Accuracy (Full Bandwidth)DSO1072E: Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns); >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns); Sample interval = s/div ÷ 200
Vertical ResolutionDSO1072E: 8-bit resolution, all channel sampled simultaneously
Volts RangeDSO1072E: 2mV/div to 10V/div at input BNC
BandwidthDSO1072E: 70MHz | DSO1102E: 100MHz | DSO1152E: 150MHz | DSO1202E: 200MHz
Rise Time at BNC( typical)DSO1072E: 5ns | DSO1102E: 3.5ns | DSO1152E: 2.3ns | DSO1202E: 1.8ns
Analog Bandwidth in Normal and Average modes at BNC or with probe, DC CoupledDSO1072E: ±50V(10V/div-5V/div) ±40V(2V/div-500mV/div); ±2V(200mV/div-50mV/div) ±400mV(20mV/div-2mV/div)
MathDSO1072E: +, -, *, /, FFT
FFTDSO1072E: Windows:Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample point
Bandwidth LimitDSO1072E: 20MHz
Low Frequency Response (-3db)DSO1072E: ≤10Hz at BNC
DC Gain AccuracyDSO1072E: ±3% for Normal or Average acquisition mode, 100V/div to 10mV/div. ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div.
DC Measurement Accuracy, Average Acquisition ModeDSO1072E: Measurement Type: Average of ≥ 16 waveforms with vertical position at zero Accuracy: ± (3% × reading + 0.1div + 1mV) when 10mV/div or greater is selected. Measurement Type: Average of ≥ 16 waveforms with vertical position not at zero Accuracy: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div].
Volts Measurement Repeatability, Average Acquisition ModeDSO1072E: Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions
Trigger TypesDSO1072E: Edge, Video, Pulse, Slope, Over time, Alternative
Trigger SourceDSO1072E: CH1, CH2, AC Line
Trigger ModesDSO1072E: Auto, Normal, Single
Coupling TypeDSO1072E: DC, AC, HF Reject, LF Reject, Noise Reject
Trigger Sensitivity (Edge Trigger Type)DSO1072E: DC(CH1,CH2): 1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full; AC: Attenuates signals below 10Hz ; HF Reject: Attenuates signals above 80kHz; LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz.
Trigger Level RangeDSO1072E: CH1/CH2: ±8 divisions from center of screen;
Set Level to 50%(typical)DSO1072E: Operates with input signals ≥50Hz
Video TriggerDSO1072E:  
Video Trigger TypeDSO1072E: CH1, CH2: Peak-to-peak amplitude of 2 divisions;
Signal Formats and Field RatesDSO1072E: Supports NTSC, PAL and SECAM broadcast systems for any field or any line
Holdoff RangeDSO1072E: 100ns ~ 10s
Pulse Width TriggerDSO1072E:  
Pulse Width Trigger ModeDSO1072E: Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse
Pulse Width Trigger PointDSO1072E: Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level. Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width. Less than: The trigger point is the trailing edge. Greater than (also called over
Pulse Width RangeDSO1072E: 20ns ~ 10s
Slope TriggerDSO1072E: &emsp;
Slope Trigger ModeDSO1072E: Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope
Slope Trigger PointDSO1072E: Equal: The oscilloscope triggers when the waveform slope is equal to the set slope. Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope. Less than: The oscilloscope triggers when the waveform slope is less than the set slope. Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
Time RangeDSO1072E: 20ns ~ 10s
Overtime TriggerDSO1072E: &emsp;
Over Time ModeeDSO1072E: Rising edge or Falling edge
Alternative TriggerDSO1072E: &emsp;
Trigger on CH1DSO1072E: Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger on CH2DSO1072E: Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger Frequency CounterDSO1072E: &emsp;
Readout ResolutionDSO1072E: 6 digits
Accuracy (typical)DSO1072E: ±30ppm (including all frequency reference errors and ±1 count errors)
Frequency RangeDSO1072E: AC coupled, from 4Hz minimum to rated bandwidth
Signal SourceDSO1072E: Pulse Width or Edge Trigger modes: all available trigger sources The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed. Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify
Cursor MeasurementDSO1072E: Manual: Voltage difference between cursors: △ V Time difference between cursors: △ T Reciprocal of △ T in Hertz (1/ΔT); Tracing: The valtage and time at a waveform point;
Auto MeasuermentDSO1072E: Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS,
Scope TrendplotDSO1072E: 1.2M Point
Display ResolutionDSO1072E: 640 horizontal by 480 vertical pixels
Display ContrastDSO1072E: Adjustable (16 gears) with the progress bar
Probe Compensator OutputDSO1072E: &emsp;
Output Voltage( typical)DSO1072E: About 2Vpp into ≥ 1MΩ load
Frequency(typical)DSO1072E: 1kHz
Power SupplyDSO1072E: &emsp;
Supply VoltageDSO1072E: AC Input:100-240VACRMS,1.5A MAX,50Hz~60Hz; DC Output: 12V,3A
Power ConsumptionDSO1072E: <30W
EnvironmentalDSO1072E: &emsp;
TemperatureDSO1072E: Operating: 32 ℉ to 122 ℉ (0 ℃ to 50 ℃ ); Nonoperating: -40 ℉ to 159.8 ℉ (-40 ℃ to +71 ℃ )
Cooling MethodDSO1072E: Convection
HumidityDSO1072E: +104 ℉ or below (+40 ℃ or below): ≤90% relative humidity; 106 ℉ to 122 ℉ (+41 ℃ to 50 ℃ ): ≤60% relative humidity
AltitudeDSO1072E: Operating: Below 3,000m (10,000 feet); Nonoperaring: Below 15,000m(50,000 feet)
MechanicalDSO1072E: &emsp;
SizeDSO1072E: 260mmmm; 220mm; 75mm
WeightDSO1072E: 2.5KG(without Packing)
HT300B,HT500BDescription: 350Mhz,500MHz,10:1/1:1 | View Manual: Download
HT-100B,HT-200BDescription: 100MHz,200MHz,10:1/1:1 | View Manual: Download