HBT3561AResistance Resolution: 0.1μΩ | Resistance Range: 0~3.6kΩ | Resistance Range: 士0.5%rdg土10dgt(3mΩ),士0.5%rdg土5dgt(30mΩ-3600Ω) | Voltage Resolution: 1μV | Voltage Range: 0~110V | Voltage Accuracy: 士0.01%rdg土3dgt | Interface: RS232/485 USB LAN IO ANALOGOUTFUT
HBT3562AResistance Resolution: 0.1μΩ | Resistance Range: 0~3.6kΩ | Resistance Range: 士0.5%rdg土10dgt(3mΩ),士0.5%rdg土5dgt(30mΩ-3600Ω) | Voltage Resolution: 1μV | Voltage Range: 0~210V | Voltage Accuracy: 士0.01%rdg土3dgt | Interface: RS232/485 USB LAN IO ANALOGOUTFUT
HBT3563AResistance Resolution: 0.1μΩ | Resistance Range: 0~3.6kΩ | Resistance Range: 士0.5%rdg土10dgt(3mΩ),士0.5%rdg土5dgt(30mΩ-3600Ω) | Voltage Resolution: 1μV | Voltage Range: 0~360V | Voltage Accuracy: 士0.01%rdg土3dgt | Interface: RS232/485 USB LAN IO ANALOGOUTFUT
HBT5563AResistance Resolution: 0.1μΩ | Resistance Range: 0~3.6kΩ | Resistance Range: 士0.5%rdg土10dgt(3mΩ),士0.5%rdg土5dgt(30mΩ-3600Ω) | Voltage Resolution: 1μV | Voltage Range: 0~360V | Voltage Accuracy: 士0.01%rdg土3dgt | Interface: RS232/485 USB LAN IO ANALOGOUTFUT
VoltageHBT3561A: Range | HBT3562A: 110V | HBT3563A: 210V | HBT5563A: 360V | HBT3564A: 360V | HBT3565A: 1100V | HBT5566A: 1600V | HBT3566A: 2000V
MeasurementHBT3561A: Max. Display | HBT3562A: 121V | HBT3563A: 231V | HBT5563A: 396V | HBT3564A: 396V | HBT3565A: 1210V | HBT5566A: 1760V | HBT3566A: 2200V
 HBT3561A: Resolution | HBT3562A: 1 μV | HBT3563A: 10 μV
ResistanceMeasurementHBT3561A: Range | HBT3562A: Max. Display | HBT3563A: Resolution | HBT5563A: Measurement Current | HBT3564A: Accuracy
3 mΩHBT3561A: 30 mΩ or more
30 mΩHBT3561A: 36 mΩ | HBT3562A: 1 μΩ | HBT3563A: 100 mA
300 mΩHBT3561A: 360 mΩ | HBT3562A: 10 μΩ | HBT3563A: 10 mA
3 ΩHBT3561A: 3.6Ω | HBT3562A: 100 μΩ | HBT3563A: 1 mA
30 ΩHBT3561A: 36Ω | HBT3562A: 1mΩ | HBT3563A: 100 μA
300 ΩHBT3561A: 360 Ω | HBT3562A: 10 mΩ | HBT3563A: 10 μA
3600ΩHBT3561A: 3610Ω | HBT3562A: 100 mΩ | HBT3563A: 10 μA
Measurement MethodHBT3561A: AC four-terminal method
Measurement FrequencyHBT3561A: 1 kHz
Response TimeHBT3561A: 5 ms approx.
Open Terminal VoltageHBT3561A: 12 V peak | HBT3562A: 15 V peak
Sampling PeriodHBT3561A: Meas. | HBT3562A: Fast | HBT3563A: Medium | HBT5563A: Slow
(Frequency: 50 Hz/60 Hz)HBT3561A: Speed
Allowable Total Line Res.(error detection)HBT3561A: Range | HBT3562A: 3 mΩ | HBT3563A: 30 mΩ | HBT5563A: 300 mΩ | HBT3564A: 3 Ω
Sense LineHBT3561A: 3 Ω | HBT3562A: 3 Ω | HBT3563A: 20Ω | HBT5563A: 20Ω
Source LineHBT3561A: 3 Ω | HBT3562A: 3 Ω | HBT3563A: 20Ω | HBT5563A: 200Ω
FunctionHBT3561A: Zero Adjustment | HBT3562A: Yes
Meas. Current Pulse OutputHBT3561A: Pulse, Continuous
Statistical CalculationsHBT3561A: Mean, Maximum, Minimum, Standard Deviation, Sample Standard Deviation, Process Capability Index (Dispersion), Process Capability Index (Deviation)
Delay TimeHBT3561A: On/Off,1 ms to 9999 ms
AverageHBT3561A: 1, 2, 4, 8 times
Save/LoadHBT3561A: Up to 1000
TriggerHBT3561A: Internal, External, Manual
InterfaceHBT3561A: Standard | HBT3562A: RS232/485, USB, LAN, I/O, Analog Output
OptionalHBT3561A: GPIB (HBT4000H series models only)
DisplayHBT3561A: 4.3 inch LCD
AC InputHBT3561A: 110 V ±10 % or 220 V ± 10 %, 47 to 63 Hz
Dimension(WxHxD)HBT3561A: Low voltage: 208.5mm*84.5mm*264mm