HomeProductsMSO5000D Series
MSO5000D Series
HANTEKOscilloscopes
Model: MSO5000D

MSO5000D Series

Price:Price on Request

4-Channel Oscilloscope/16-Channel Logic Analyzer/Spectrum Analyzer/2-Channel Arbitrary Wave Generator/Digital Voltmeter/6-bit Frequency Meter and Accumulator/Protocol Analyzer/Protocol Generator

Key Specifications

Sample RateMSO5202D: Real-Time Sample: 1GS/s
Acquisition ModesMSO5202D:
NormalMSO5202D: Normal data only
Peak DetectMSO5202D: High-frequency and randon glith capture
Contact Us
View on Manufacturer's Website
Sample RateMSO5202D: Real-Time Sample: 1GS/s
Acquisition ModesMSO5202D:
NormalMSO5202D: Normal data only
Peak DetectMSO5202D: High-frequency and randon glith capture
AverageMSO5202D: Waveform Average, selectable 4,8,16,32,64,128
Inputs CouplingMSO5202D: AC, DC, GND
Inputs ImpendanceMSO5202D: 1MΩ±2% ‖ 20pF±3pF
Probe AttenuationMSO5202D: 1X, 10X
Supported Probe Attenuation FactorMSO5202D: 1X, 10X, 100X, 1000X
Maximum Input VoltageMSO5202D: CAT I and CAT II: 300VRMS (10×), Installation Category; CAT III: 150VRMS (1×); Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited t
Sample Rate RangeMSO5202D: 500MS/s--1GS/s
Waveform InterpolationMSO5202D: (sin x)/x
Record LengthMSO5202D: 1M
SEC/DIV RangeMSO5202D: 2ns/div to 40s/div, | MSO5102D: 8ns/div to 40s/div
Sample Rate and Delay Time AccuracyMSO5202D: ±50ppm ( at over any ≥1ms time interval)
Position RangeMSO5202D: 2ns/div to 8ns/div; (-8div x s/div) to 20ms; | MSO5102D: 20ns/div to 80us/div; (-8div x s/div) to 40ms; 200us/div to 40s/div; (-8div x s/div) to 400s;
Delta Time Measurement Accuracy (Full Bandwidth)MSO5202D: Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns); >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns); Sample interval = s/div ÷ 200
Vertical ResolutionMSO5202D: 8-bit resolution, all channel sampled simultaneously
BandwidthMSO5202D: 200MHz | MSO5102D: 100MHz | MSO5062D: 60MHz
Rise Time at BNC( typical)MSO5202D: 1.8ns | MSO5102D: 3.5ns | MSO5062D: 5.8ns
Offset RangeMSO5202D: 2mV/div to 20mV/div, ±400mV 50mV/div to 200mV/div, ±2V 500mV/div to 2V/div, ±40V 5V/div to 10V/div, ±50V
MathMSO5202D: +, -, *, /, FFT
FFTMSO5202D: Windows: Hanning 、 Flatop 、 Rectamgular 、 Bartlett 、 Blackman; 1024 sample point
Bandwidth LimitMSO5202D: 20MHz
Low Frequency Response (-3db)MSO5202D: ≤10Hz at BNC
DC Gain AccuracyMSO5202D: ±3% for Normal or Average acquisition mode, 10V/div to 10mV/div; ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div
DC Measurement Accuracy, Average Acquisition ModeMSO5202D: When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected; When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 10V/div
Volts Measurement Repeatability, Average Acquisition ModeMSO5202D: Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions
Trigger TypesMSO5202D: Edge, Video, Pulse, Slope, Over time, Alternative
Trigger SourceMSO5202D: CH1, CH2, EXT, EXT/5, AC Line
Trigger ModesMSO5202D: Auto, Normal, Single
Coupling TypeMSO5202D: DC, AC, Noise Reject, HF Reject, LF Reject
Trigger Sensitivity (Edge Trigger Type)MSO5202D: DC(CH1,CH2): 1div from DC to 10MHz;1.5div from 10MHz to 100MHz; 2div from 100MHz to Full; DC(EXT): 200mV from DC to 100MHz; 350mV from 100MHz to 200MHz; DC(EXT/5): 1V from DC to 100MHz;1.75V from 100MHz to 200MHz; AC: Attenuates signals below 10Hz HF Reject: Attenuates signals above 80KHz; LF Reject: Same as the DC-coupled limits for frequencies above 150KHz; attenuates signals below 150
Trigger Level RangeMSO5202D: CH1/CH2: ±8 divisions from center of screen; EXT: ±1.2V; EXT/5:±6V
Set Level to 50%(typical)MSO5202D: Operates with input signals ≥50Hz
Video TriggerMSO5202D:
Video Trigger TypeMSO5202D: CH1, CH2: Peak-to-peak amplitude of 2 divisions; EXT: 400mV; EXT/5: 2V
Signal Formats and Field Rates, Video Trigger TypeMSO5202D: Supports NTSC, PAL and SECAM broadcast systems for any field or any line
Holdoff RangeMSO5202D: 100ns ~ 10s
Pulse Width TriggerMSO5202D:
Pulse Width Trigger ModeMSO5202D: Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse
Pulse Width Trigger PointMSO5202D: Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level. Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width. Less than: The trigger point is the trailing edge. Greater than (also called over
Pulse Width RangeMSO5202D: 20ns ~ 10s
Slope TriggerMSO5202D:
Slope Trigger ModeMSO5202D: Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope
Slope Trigger PointMSO5202D: Equal: The oscilloscope triggers when the waveform slope is equal to the set slope. Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope. Less than: The oscilloscope triggers when the waveform slope is less than the set slope. Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
Time RangeMSO5202D: 20ns ~ 10s
Overtime TriggerMSO5202D:
Over Time ModeMSO5202D: Rising edge or Falling edge
Alternative TriggerMSO5202D:
Trigger on CH1MSO5202D: Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger on CH2MSO5202D: Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger Frequency CounterMSO5202D:
Readout ResolutionMSO5202D: 6 digits
Accuracy (typical)MSO5202D: ±30ppm (including all frequency reference errors and ±1 count errors)
Frequency RangeMSO5202D: AC coupled, from 4Hz minimum to rated bandwidth
Signal SourceMSO5202D: Pulse Width or Edge Trigger modes: all available trigger sources The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed. Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify
Cursor MeasurementMSO5202D: Voltage difference between cursors: △ V Time difference between cursors: △ T Reciprocal of △ T in Hertz (1/ΔT)
Auto MeasuermentMSO5202D: Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF
ChannelsMSO5202D: 16 Channels
Max. Input ImpendenceMSO5202D: 200K(C=10p)
Input Voltage RangeMSO5202D: -60V~60V
Logic Threshold RangeMSO5202D: -8V~8V
Max. Sample RateMSO5202D: 500MHz
Compatible InputMSO5202D: TTL, CMOS, ECL
Sample DepthMSO5202D: 512K
TriggerMSO5202D:
Edge TriggerMSO5202D: D0-D15 select slope (rising or falling edge)
Pulse WidthMSO5202D: D0-D15 select pulse polarity (positive or negative pulse), trigger when (=, ≠, >, <), trigger pulse width
Code-typeMSO5202D: D0-D15 select code-type (H, L, X)
DurationMSO5202D: D0-D15 select persist time and trigger when (data terminate, data start, and data delay)
QueueMSO5202D: D0-D15 select specific data index (0-3) and code-type (H, L, X)
RepeatMSO5202D: D0-D15 select code-type (H, L, X) and repeat times
DisplayMSO5202D:
Display TypeMSO5202D: 7 inch 64K color TFT (diagonal liquid crystal)
Display ResolutionMSO5202D: 800 horizontal by 480 vertical pixels
Display ContrastMSO5202D: Adjustable (16 gears) with the progress bar
Probe Compensator OutputMSO5202D:
Output Voltage( typical)MSO5202D: About 5Vpp into ≥1MΩ load
Frequency(typical)MSO5202D: 1kHz