HANTEKRF & Signal
Model: HSA2016
HSA2016 Series
Price:Price on Request
IP-51 High protection portable design, sturdy and durable, can be used in laboratory, more suitable for field mobile use.
Key Specifications
ModelHSA2016A / HSA2016B
Frequency Range9KHz~1.6GHz AC Coupled / 9KHz~1.6GHz AC Coupled 5M~1.6GHz TG
Frequency Resolution1Hz
Reference Frequency10MHz
ModelHSA2016A / HSA2016B
Frequency Range9KHz~1.6GHz AC Coupled / 9KHz~1.6GHz AC Coupled 5M~1.6GHz TG
Frequency Resolution1Hz
Reference Frequency10MHz
Frequency Readout Accuracy±(frequency indication*frequency reference uncertainty+1%*span+20%RBW+marker resolution+1Hz)
Internal 10MHz Reference AccuracyAging rate / ±1ppm/year ( 0 ℃ ~50 ℃ , Reference is 25 ℃ )
Temperature stability±1ppm/year
Marker Resolution(Frequency span)/(number of sweep points-1)
-3dB Bandwidth10Hz to 1MHz , 1-3-10 sequence
Accuracy±5% RBW=10Hz~1MHz nominal
Resolution Filter Shape Factor< 5:1 nominal
Video Bandwidth ( VBW )-3dB bandwidth / 1Hz to 1MHz , 1-3-10 sequence
9K~1MHzPreamp off / -108dBm , typical -127dBm
1MHz ~10MHz-128dBm , typical -146dBm
10MHz ~500MHz-142dBm , typical -146dBm
500MHz ~2.5GHz-141dBm , typical -145dBm
2.5GHz ~3GHz-140dBm , typical -144dBm
Carrier Offset(20 ℃ ~ 30 ℃, 500MHz Central Frequency )10K / < -92 dBc/Hz, typical -95 dBc/Hz
30K< -93 dBc/Hz, typical -96 dBc/Hz
100K< -95 dBc/Hz, typical -97 dBc/Hz
1MHz< -117 dBc/Hz, typical -119 dBc/Hz
RangeSpan >100Hz / 2ms to 1000s
Span=0Hz600ns to 200s
Sweep ModeContinuous, single
Trigger SourceFree run; video; external
Trigger slopeSelectable positive or negative edge
Trigger delaySpan =0Hz / ±12ms to ±12s nominal
Counter Resolution1Hz
Log Scale and Units1 to 10 dB/divisions in 1, 2, 5, 10 dB steps, 10 divisions displayed
Linear Scale and Units0 to 100% , 10 divisions displayed
Scale UnitdBm , dBmV,dBuV,Watts , Volts
Sweep (Trace) Points461
Number of Markers4
DetectorsNormal, positive peak, dample, negative peak, RMS
Number of Traces4
Trace FunctionsClear/write, maximum hold, minimum hold, average, check , close
Level Measurement Error± 1.5dB(excluding input VSWR mismatch) 20~30 ℃, peak detector, preamplifier off, input signal -50dBm to 0dBm
Setting Range-100dBm to +30dBm, steps of 1dB
Setting ResolutionLog scale / 0.01dB
Linear scaleAlmost log ( 2.236μV to 7.07V )
Maximum Safety Input LevelAverage continuous power / +33dBm
DC input voltage50Vdc
Measurement Range9KHz~2MHz / Displayed average noise level (DANL) to +10dB
2MHz~3GHzDisplayed average noise level (DANL) to +20dB
Input attenuator range0 to 51dB,1dB steps
Second Harmonic Distortion ( SHD )<65dBc , 50MHz to 3GHz ( Mixer level -30dBm , attenuator =0dB , preamp off , 20 ℃ ~30 ℃ )
Input Related Spurious<-75dBc , (input mixer = -30dBm)
Residual response (inherent)<-90dBm , typical -98dBm (Input terminated and 0 dB RF attenuation, preamplifier off)
RF Input VSWR (at Tuned Frequency)10MHz to 1.6GHz / < 1.5:1, nominal Attenuator setting 10~20dB
Reference Iinput Frequency10MHz
Reference Input Amplitude0~10dBm
Trigger Voltage5V TTL level
Connector and Output ImpendenceN female ;( 50Ω )
Interface LanguageEnglish , Chinese , Chinese Traditional
Display Index5.7 inch , 640*480 resolution , 64M color LCD display
Temperature RangeWorking / -10 ℃ to +50 ℃ ,( battery : 0 ℃ to 50 ℃ )
Storage-40 ℃ to +70 ℃ ,( battery :-20 ℃ to 50 ℃ )
Relative Humidity<95%
Weight2.9kg ( with battery ), 2.6kg ( without battery )
Size260m X 220m X 75m
PowerInput voltage range / DC: 12-17V, maximum 2.8A input 220VAC±15%
AC frequency range40Hz to 60Hz
Power consumptionMaximum 32W